64
Chapter 6 Command Definitions
6.5.25 CNXCI – Configuration Cross Connect Initiate
Synopsis
This command initiates a cross connect path across the Signaling Gateway between 2 PCM timeslots; the
incoming timeslot (ITS) and the outgoing timeslot (OTS). If DUPLEX is not set to Y, a simplex cross connect
is initiated from ITS to OTS.
Syntax
CNXCI:OTS=,ITS=,[DUPLEX=];
Prerequisites
• The PCM on which the OTS exists must have already been initiated and the OTS must be within the
correct range for the PCM type (0 to 31 for E1 and 1 to 24 for T1 PCMs).
• The PCM on which the ITS exists must have already been initiated and the ITS must be within the correct
range for the PCM type (0 to 31 for E1 and 1 to 24 for T1 PCMs).
• OTS is not already assigned elsewhere on the system for output.
• ITS is not already assigned elsewhere on the system for input.
Attributes
CONFIG
Examples
CNXCI:OTS=1-1-16,ITS=2-1-16,DUPLEX=Y;
6.5.26 CNXCE – Configuration Cross Connect End
Synopsis
This command ends a Cross Connect connection across the converter.
Syntax
CNXCE:OTS=,[DUPLEX=,];
Prerequisites
• The OTS must already be initiated as an OTS in a Cross Connect connection path.
• If DUPLEX=Y is specified, a duplex connection must already exist for the specified OTS.
Attributes
CONFIG
Examples
CNXCE:OTS=1-1-16;