6.6.11 C7SLE – CCS SS7 Signaling Link End
Synopsis
This command is used to end an SS7 signaling link.
Syntax
C7SLE:C7LINK=;
Prerequisites
• The signaling link must be blocked.
• The signaling link must not be monitored.
Attributes
CONFIG
Examples
C7SLE:C7LINK=1;
6.6.12 C7SLP – CCS SS7 Signaling Link Print
Synopsis
This command is used to obtain a printout of the attributes of SS7 signaling link(s). If no link is specified, all
initialized links are output.
Syntax
C7SLP:[C7LINK=…];
Prerequisites
None
Attributes
None
Examples
C7SLP:C7LINK=1;
C7SLP;
Output Format
Signaling Link Configuration
C7LINK EQU TS SNLINK LS SLC M56K PCR
1 1-1 1-3-16 1 0 0 N
2 1-2 2-3-16 1 1 0 N
3 1 2 0 0 N
4 2 2 1 0 N
EXECUTED