Dialogic SS7G2X Server User Manual


 
37
Dialogic
®
SS7G2x Signaling Server SGW Mode User Manual Issue 4
5.2 Remote Operations
Table 3 gives the possible remote operation types.
TIME
Time of day in the format:
xx:yy:zz
where:
xx – 2 digit hour
yy – 2 digit minute
zz – 2 digit second
xx – 00 to 23
yy – 00 to 59
zz – 00 to 59
TLO Auto log off time (in minutes) 1 to 60 Default = 30
TLOW Log off warning time (in minutes) 0 to 60 Default = 25
TMSEC
Timer values in milliseconds associated with
a timer number (resolution is 100ms)
100 to 10000
(in integer multiples
of 100)
TO
Signaling system dependent timer number.
As specified in the particular signaling
system’s list of timers.
1 to 999
TS
A timeslot within a PCM interface on a board
in the format:
xx-y-zz
where:
xx = board position (BPOS)
y = PCM within a board
zz= Timeslot
xx – 1 to 3
y – 1 to 4
zz – 1 to 31
TSEC
Timer values in seconds associated with a
timer number
1 to 3000
TTYPE
Timer Type
See Section 5.3, “Signaling Gateway
Timers” on page 38 for definitions of
Signaling Gateway “CONV” specific timers.
One of:
•MTP3
•MTP3A
•SCTP
•CONV
USER User name
0 to 12
<text character>
Table 2. Parameter Definitions (Continued)
Name Description Range Notes
Table 3. Remote Operation Types
DTYPE Description
SOFTWARE Selecting this operation allows the user to upload a new software version.
CONFIG
Selecting this operation allows the user to upload a previously backed up version of the
configuration.
LICENSE Selecting this operation allows the user to upload new software licenses.