Chapter 6 Command Definitions
6.4.4 ALLIP – Alarm List Print
Synopsis
This command gives a printout of all ACTIVE fault codes stored in the system’s alarm log.
Each fault code (CODE) is associated with an alarm class (CLA) which may be Minor, Major or Critical. The
alarm class in turn governs which alarm LED, relay or SNMP alarm is activated when the condition exists.
The command provides an indication of the time that the alarm occurred (OCCURRED), the alarm class (CLA
indicating either a System, PCM or signaling failure) as well as an alarm code specific identifier (ID) and
diagnostic field (DIAG).
See Chapter 8, “Alarm Fault Code Listing” for the definitions of the alarm code specific parameters.
Note: The meaning of the ID field depends on the alarm code and is described in Chapter 8, “Alarm
Fault Code Listing”.
Syntax
ALLIP;
Prerequisites
None
Attributes
None
Examples
ALLIP;
Output Format
SYSTEMIDENT1 Alarm List (active alarms) 1996-12-01 00:00:54
ALP CODE ID DIAG CLA OCCURRED CLEARED TITLE
107 1 103 0 1 A 2001-10-30 10:54:48 PCM loss
74 1 104 0 2 A 2001-10-30 10:54:27 PCM loss
EXECUTED