D-Link DES-3250TG Switch User Manual


 
D-Link DES-3250TG Standalone Layer 2 Switch
Figure 9- 14. Rx Size Analysis window (table)
The following fields can be set:
Parameter Description
Time Interval [1s ]
Select the desired setting between 1s and 60s,
where “s” stands for seconds. The default
value is one second.
Record Number [200]
Select number of times the Switch will be
polled between 20 and 200. The default value
is 20.
64
The total number of packets (including bad
packets) received that were 64 octets in
length (excluding framing bits but including
FCS octets).
65-127
The total number of packets (including bad
packets) received that were between 65 and
127 octets in length inclusive (excluding
framing bits but including FCS octets).
128-255
The total number of packets (including bad
packets) received that were between 128 and
255 octets in length inclusive (excluding
framing bits but including FCS octets).
256-511
The total number of packets (including bad
packets) received that were between 256 and
511 octets in length inclusive (excluding
136