16 Unpacking and Setup
Power On
The Switch can be used with AC power sources 100 - 240 VAC, 50 - 60 Hz. The power switch is located at the
rear of the unit adjacent to the AC power connector and the system fan. The Switch’s power supply will adjust
to the local power source automatically and may be turned on without having any or all LAN segment cables
connected.
After the power switch is turned on, the LED indicators should respond as follows:
All LED indicators will momentarily blink. This blinking of the LED indicators represents a reset of the
system.
The power LED indicator will blink while the Switch loads onboard software and performs a self-test.
After approximately 40 seconds, the LED will light continuously to indicate the Switch is in a ready
state.
The console LED indicator will remain ON if there is a connection at the RS-232 port, otherwise this
LED indicator is OFF.
The 100M LED indicator may remain ON or OFF depending on the transmission speed.
Power Failure
As a precaution, the Switch should be unplugged in case of power failure. When power is resumed, plug the
Switch back in.