Edirol V-44SW E1 Switch User Manual


 
61
REMOTE Command Reference
OUT OUTPUT FORMAT Button Select
stxOUT:a;
a
: 0–2 (0: 1080i, 1: 720p, 2: RGB)
This selects the OUTPUT FORMAT button, changing the format of
the video output.
ACK is returned by the V-44SW upon proper reception of the
command.
FAD OUTPUT FADE Operation
stxFAD:a;
a
: OUTPUT FADE status
(0–255, 0: FADE MAX, 255: VIDEO MAX)
This sets the concentration during fadeouts of the video output
from the HD/RGB OUT PGM connectors.
ACK is returned by the V-44SW upon proper reception of the
command.
RST V-44SW Reset
stxRST;
This resets the V-44SW’s panel status, with the Factory Presets
called up.
ACK is returned by the V-44SW upon proper reception of the
command.
VER Version Information Request
stxVER;
Transmit this when you want to check the V-44SW’s version. The
version information is returned.
* For more details on version information, refer to “VER Version
Information” on this page.
ACS Active Sensing Request
stxACS;
Transmit this when you want to check the V-440HD’s status.
ACK is returned when no operation is being performed by the
V-44SW.
DAT Data Transmission
stxDAT:aaaa,bbbb;
aaaa
: Address (aaaa, bbbb are in hexadecimal)
bbbb
: Data
This overwrites the data at the specified address.
After the required data is transmitted, FFFF,xxxx; is transmitted as
the final string of the command, and the data is written (xxxx
represents the data version).
ACK is returned when no operation is being performed by the
V-44SW.
* The “Serial Data Tool” application are available from the Roland
Systems Group website. For more detailed information, refer to
the column “Serial Data Transmissions” on this page.
XON Flow Control
XON
XOFFFlow Control
XOFF
In the following, stx (02H), ACK (06H), and Xon (11H) / Xoff (13H) are
control codes.
ACK Acknowledgment of Proper Reception
ACK
This is transmitted when a command is received properly.
ERR Error Information
stxERR:a;
a
: 0 (syntax error)
Error in the syntax of the received command.
2 (busy error)
V-44SW busy, command cannot be processed.
5 (out of range error)
Number in received command is out of range.
20 (some thing error)
Other error. Transmitted when the V-44SW is unable to process
the command properly
VER Version Information
stxVER: “a”, “b”, “c”;
a
: Model Name (V-44SW)
b
: Version
c
: Rese
rved
This is transmitted when the V-440SW receives a VR command
version. The version information is transmitted as an ASCII
character string.
DAT Data Transmission
stxDAT:aaaa,bbbb;
aaaa
: Address (aaaa, bbbb are in hexadecimal)
bbbb
: Data
The data is transmitted to the specified address.
After the required data is transmitted, FFFF,xxxx; is transmitted as
the final string of the command, and the data is written (xxxx
represents the data version).
* The “Serial Data Tool” application are available from the Roland
Systems Group website. For more detailed information, refer to
the column “Serial Data Transmissions” on this page.
XON Flow Control
XON
XOFFFlow Control
XOFF
Commands Transmitted from the
V-44SW to External Devices
Serial Data Transmissions
The following data and application have been made available by
the Roland system Group. You may download and use these
materials.
http://rolandsystemsgroup.net
“Serial Data Tool” V-440HD settings backup and restore tool
(for Windows XP only)
The “Serial Data Tool” for the V-440HD may also be used with
the V-44SW.
V-44SW_e.book 61 ページ 2006年10月23日 月曜日 午後3時25分