14.
Grasp the donor's leading end and slowly insert the donor
magazine along the guide.
NOTE: Push the donor magazine all the way in.
15.
Close the inner door and rotate the inner door lock lever 90
degrees clockwise.
16.
Close the front lower door.
★ When the self-check is completed, the message changes
to "Data Ready".
IMPORTANT:
● During the cutting of the leading edge, LED lamps 1 to
10 on the transfer monitor come on sequentially. At this
time, do not open any door. If you do, donor/receiver
jamming may occur.
● During the cutting of the leading edge, do not turn the
power switch to OFF (
) or unplug the power cable. If
you do, donor/receiver jamming may occur.
3.4 Donor Magazine Replacement
Guide
Inner Door Lock Lever
Inner Door
Data Ready400