57
4
HOW TO USE THE OPERATION PANEL
To enable the donor, receiver, and water filter counters and to set the quantity of remaining donor,
receiver, and water filter prior to replacement, follow the procedure below.
4.9 Setting the Consumables Counters
1
.
Press the ONLINE key on the operation panel to switch
the machine to OFFLINE condition.
2
.
When the machine is in OFFLINE mode, press the NEXT
key twice.
★ The message changes to "Configuration".
3
.
Press the SEL key.
★ The message changes to "Size".
4
.
Press the NEXT key eight times.
★ The message changes to "Counter".
5
.
Press the + or – key to select whether the counters are
enabled or not.
★ When "Enable" is selected, the " " mark is displayed
on the SEL key, and the user can enter the quantity for
each consumables remaining until replacement is
required.
■ To set the remaining quantity of donor
6
.
Press the SEL key.
★ The message changes to "Donor Count".
7
.
Press the + or – key to set the remaining quantity of donor.
■ To set the remaining quantity of receiver
8
.
Press the NEXT key.
★ The message changes to "Paper Count".
9
.
Press the + or – key to set the remaining quantity of receiver.
■ To enter the remaining processing capability available
with the currently loaded water
10.
Press the NEXT key.
★ The message changes to "Filter Count".
11.
Press the + or – key to set the remaining processing
capability available with the currently loaded water.
12.
Press the ONLINE key to return to the machine to ONLINE
condition.
Configuration
ESC
PREV
SEL
NEXT
ON LINE
Counter
[ ]
Enable
+
[ ]
–
ESC
PREV
SEL
NEXT
Donor Count
[ ]
130
+
[ ]
–
ESC
PREV
SEL
NEXT
Paper Count
ESC
PREV
SEL
NEXT
[ ]
130
+
[ ]
–
Filter Count
ESC
PREV
SEL
NEXT
[ ]
130
+
[ ]
–
Size
ESC
PREV
SEL
NEXT
[ ]
DP
+
[ ]
–