Zebra XiII Printer User’s Guide 39
Operation
Media and Ribbon Sensor Sensitivity Press Next/Save to skip this procedure and continue with
“Setting Host Port” below. Press the right oval key to start the calibration procedure.
This procedure is used to adjust the sensitivity of the Media and Ribbon Sensors.
Note: The procedure must be followed exactly as presented. All steps must be performed even if
only one of the sensors requires adjustment.
1. Press: 2. Display Shows: Action/Explanation:
Press the left oval key to cancel the operation, or do the following:
Open the Printhead. Remove as many labels as needed to load a
section of blank backing material under the media sensor (just
behind the printhead). See Figure 4, “Upper Media Sensor Adjust-
ment,” on page 16 to locate the sensor.
Press the left oval key to cancel the operation or do the following:
1) Remove the ribbon (sliding it as far to the right as possible will
have the same effect as removing it.)
2) Close the Printhead.
The printer automatically adjusts the scale (gain) of the signals it
receives from the media and ribbon sensors based on the specific
media and ribbon comb
ination you are using. On the sensor
profile, this essentially corresponds to moving the graph up
or down to optimize the readings for your application.
—
When “ ” is displayed:
1) Open the Printhead and pull the media forward until a label is
positioned under the Media Sensor.
2) Move the ribbon back to its proper position.
3) Close the Printhead.
Now that the scale has changed, the printer performs a calibration
equivalent to pressing the Calibrate key. During this process, the
printer checks the readings for the media and ribbon based on the
new scale you’ve established, determines the label length, and
determines whether you are in thermal direct or thermal transfer
print mode. The process is now complete! To see the new readings
on the new scale, print a Sensor Profile (above).