Use the following section to help resolve issues with slides, negatives,
and other transparent media scanned using the XPA. All actions must
be performed in the HP PrecisionScan Pro software, because you
must scan slides, negatives, and other transparent items using this
software. See also "Resolving issues with the XPA" on page 95.
,WULHGWRHQODUJHDVFDQQHGLPDJHRIDVOLGHEXWWKHLPDJH
UHPDLQHGWKHVDPHVL]H
You might have used the Zoom In command, which only changes
the view on the screen. Use the Resize command to change the
size of the final scanned image. See "Resizing (output
dimensions)" on page 38.
7KHFRORUVDUHLQFRUUHFWRUWKHLPDJHLVWRROLJKWRUWRRGDUN
The software might be setting exposure for the entire area
instead of one slide or negative. Create a selection area around
the slide or negative you want to use to ensure it is exposed
correctly.
The template is not placed completely on the scanner glass.
Make sure the template is completely on the scanner glass.
7KHVFDQQHGLPDJHVKRZVDFRORUHGWLQWXVXDOO\SLQN
The slide was probably scanned without using the slide template,
or the template was placed incorrectly. Use the included slide
template to scan slides. Turn the template so the wording Hewlett
Packard is at the top, or closest to the hinged portion of the lid.
6FDQQHGLPDJHVDSSHDUDVDER[ZLWKPXOWLFRORUHGYHUWLFDOOLQHVRU
DVDGDVKHGER[ZLWKDQDUURZVXUURXQGLQJWKHDUHD
The template might be placed incorrectly on the scanner bed. Turn
the template so the wording Hewlett Packard is at the top, or
closest to the hinged portion of the lid.
7KHVFDQQHGLPDJHLVEODFNHYHQWKRXJKWKHOLJKWVRQWKH
WUDQVSDUHQF\DGDSWHUDUHRQ
The template might be placed incorrectly on the scanner bed.
Turn the template so the wording Hewlett Packard is at the top,
or closest to the hinged portion of the lid.
Check the Adjust Exposure command in the Advanced menu.
7KHUHDUHVWUHDNVLQWKHVFDQQHGLPDJH
Check the original slide or negative for damage.
The calibration area at the top of the large template might be
scratched or blemished. If there are scratches or blemishes, turn
the template over and scan again to see if the streak moves to
the other side of the scan. If the streaks move, then the template
needs to be replaced.
7KHVFDQVDUHGDUNRUGLPDORQJRQHVLGHRIWKHLPDJH
One of the two bulbs in the XPA might be broken or not working.
With the XPA connected to the scanner, hold the XPA up and look
for even illumination on both sides of the XPA. If a bulb is broken,
service is required.