HP (Hewlett-Packard) CE863A All in One Printer User Manual


 
4. In the following step, the connector and guide will be separated from the fuser. You must not use
too much force and damage the lower portion of the guide. If the guide is damaged, the fuser
must be replaced.
Figure 1-140 Remove the fuser (4 of 8)
5. Carefully disconnect one connector (callout 1) and then rotate the connector and the top portion of
the guide away from the fuser.
CAUTION: Do not separate the connector and guide more than is shown in Figure 1-140
Remove the fuser (4 of 8) on page 103. If the guide is damaged, you must replace the fuser. Do
not damage the connector.
Figure 1-141 Remove the fuser (5 of 8)
1
ENWW
Removal and replacement procedures
103