Document feeder pickup roller assembly
IMPORTANT: The document feeder pickup roller must be shipped in the down position.
1. Open the document feeder cover.
2. Disconnect one spring (callout 1).
Figure 1-10 Remove the document feeder pickup roller assembly (1 of 2)
1
3. Lift up on the end of the assembly, and then slide it toward the control panel to remove it.
Figure 1-11 Remove the document feeder pickup roller assembly (2 of 2)
2
1
16 Chapter 1 Removal and replacement ENWW