Hitachi L2002 Power Supply User Manual


 
“A” Group: Standard Functions
Configuring
Drive Parameters
3–20
A244 V/f characteristic curve
selection, 2nd motor
Two available V/f curves;
three select codes:
00... Constant torque
01... Reduced torque
✘ ✘ 00 00
2CTRL C-TRQ
A045 V/f gain setting Sets voltage gain of the
inverter, range is 20. to 100.%
✔ ✔ 100. 100. %
V-Gain 00100%
A245 V/f gain setting, 2nd
motor
Sets voltage gain of the
inverter, range is 20. to 100.%
✔ ✔ 100. 100. %
2V-Gain 00100%
“A” Function Run
Mode
Edit
Lo Hi
Defaults
Func.
Code
Name /
SRW Display
Description
–FE(F)
(EU)
–FU
(USA)
Units