HUAWEI MC509 CDMA LGA Module
AT Command Interface Specification
SAR Commands
Issue 01 (2011-08-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
131
13 SAR Commands
13.1 ^BODYSARON–Disable or Enable Body SAR
13.1.1 Syntax
Command
Possible Response(s)
^BODYSARON=<on
>
In case of successful execution:
<CR><LF>OK<CR><LF>
In case of an error during command execution:
<CR><LF>ERROR<CR><LF>
^BODYSARON?
In case of successful execution:
<CR><LF>^BODYSARON:<on><CR><LF>
<CR><LF>OK<CR><LF>
In case of an error during command execution:
<CR><LF>ERROR<CR><LF>
^BODYSARON=?
<CR><LF>^BODYSARON:(0,1)<CR><LF>
<CR><LF>OK<CR><LF>
13.1.2 Interface Description
This command is used to enable or disable the BodySAR function. Read command
can queries current state for BodySAR function, Test command returns supported
value of set command.
13.1.3 Parameter Description
< on>: state of BodySAR function
0: disable Body SAR (default).
1: Enable Body SAR.