6.8.7.1 Migration/Purge Server Configuration Variables
Table 6-22 liststhe fields on the HPSS Migration/Purge Server Configurationwindow and provides
specific recommendations for configuring the MPS for use by HPSS.
Table 6-22 Migration/Purge Server Configuration Variables
Display Field Name Description Acceptable Values
Default
Value
Server Name The descriptive name of
the MPS. This name is
copied over from the
selected MPS general
configuration entry.
This field cannot be modified. It is
displayed for reference only.
The selected
MPS
descriptive
name.
Server ID The UUID of the MPS.
This ID is copied over
from the selected MPS
general configuration
entry.
This field cannot be modified. It is
displayed for reference only.
Extracted
from the MPS
general
configuration
entry.
Storage Class Update
Interval
The interval, in seconds,
that indicates how often
the MPS will query each
SS to get the latest data on
each storage class that the
SS manages. This is also
the interval the MPS uses
to check periodically to
see whether it needs to
initiate a purge operation
on the storage class based
on the associated purge
policy.
Any positive integer between 10
and 600.
60 seconds