Intel SRCU31 Computer Hardware User Manual


 
Intel® Server RAID Controller U3-1 User’s Manual Rev 1.0 C-1
Error Messages Defined C
C.1 Summary of Contents
Error Messages
RAID Configuration Utility Error Messages
Flash Recovery Utility (FRU) Error Messages
High Level Errors
Internal Errors
Warning Messages
Firmware Update Utility (FUU) Error Messages
Firmware Update Utility (FUU) Internal Errors (Error Code Range = 1500 to 1599)
Firmware Update Utility Errors (Error Code Range = 1600 to 1749)
Firmware Update Utility Warnings (Error Code Range = 1750 to 1999)
C.2 Error Messages
C.2.1 RAID Configuration Utility Error Messages
For Internal Errors 4000 – 4099, contact your server OEM for support.
C.2.2 Flash Recovery Utility (FRU) Error Messages
C.2.2.1. High Level Errors
"ERROR 2100: Either RAID Adapter card is not present or Flash Programming
Jumper on the RAID Adapter card is not set. Please turn off the system and
perform following checks:
1. Check if the RAID Adapter card is present in the system
2. Check if the Flash Programming Jumper is set as specified in the User's
Manual
And then restart the program."
This message is generated when the FRU fails to find any IOP in reset mode 0. This means that
either there is no IOP hardware present at all in the computer or the Flash Programming Jumper on
the IOP hardware is not properly set. The FRU can not perform any action without having an IOP
in reset mode 0. Hence the only option is to exit the program. The user is prompted to press any key
to exit the FRU.
"ERROR 2101: Multiple RAID Adapter cards found in the system. Please turn
off the system. Keep only one RAID Adapter card in the system and
restart."