Chapter 2 — Configuring the CK30
36 CK30 Handheld Computer User’s Manual
All configuration responses are routed with the
$NGCFGRSP transaction ID. The DCS 30X or Intermec
Gateway cannot keep track of multiple applications sending
reader or configuration commands. If you have two host
applications sending reader or configuration commands, they
must both be configured to receive the $NGCFGRSP
transactions, and therefore both will receive all responses from
all CK30s.
To set up the host computer
• Verify that the host computer can communicate with the
DCS 30X or Intermec Gateway.
To set up the application
• Prepare and write a host application that can communicate
with the DCS 30X or Intermec Gateway and send
transactions to and receive transactions from the CK30 in this
format:
transaction header TMF field commands
where:
transaction is a 96-byte field containing the message
header number, date and time, source application ID,
destinations application ID, transaction ID,
and other information. You must set the system
message (SYS$MSG) flag to E in the
transaction header. For help, see the DCS 30X
or Intermec Gateway user’s manual.