Lenovo RS210 Server User Manual


 
To install a drive cage, complete the following steps:
1. Make sure that the backplane or back plate is removed from the drive cage. (See “Removing the
backplane or back plate (3.5-inch drives)” on page 154 or “Removing the SAS backplane (2.5-inch
drives)” on page 156 for instructions, as applicable.)
2. Line up the drive cage with the drive bays on the front of the server.
3. Push the drive cage into the server until it stops.
4. Align the holes in the top of the drive cage with the holes in the top of the chassis; then, insert the
screws that secure the drive cage to the chassis.
5. Install the backplane or back plate. (See “Installing the backplane or back plate (3.5-inch drives)” on
page 154 or “Installing the SAS backplane (2.5-inch drives)” on page 157 for instructions, as
applicable.)
6. Install the hard disk drives.
7. Go to “Completing the FRU replacement” on page 173.
Replacing the microprocessor and heat sink
The following notes describe the type of microprocessor that the server supports and other information
that you must consider when you install a microprocessor:
v The server supports one Intel land grid array (LGA) 1156 dual-core or quad-core microprocessor. The
type, speed, and L3 cache of the microprocessor depends on the server model.
v Read the documentation that comes with the microprocessor to determine whether you have to update
the server firmware. To download the most current level of server firmware, go to
Chapter 6. Replacing FRUs 139