Lenovo RS210 Server User Manual


 
4. After you install ASU, Type the following commands to set the DMI:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model> [access_method]
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> [access_method]
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag> [access_method]
Where:
<m/t_model>
The server machine type and model number. Type mtm xxxxyy, where xxxx is the machine
type and yyy is the server model number.
<s/n> The serial number on the server. Type sn zzzzzzz, where zzzzzzz is the serial number.
<asset_method>
The server asset tag number. Type asset aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa, where
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the asset tag number.
[access_method]
The access method that you select to use from the following methods:
v Online authenticated LAN access, type the command:
[host <imm_internal_ip>] [user <imm_user_id>][password <imm_password>]
Where:
imm_internal_ip
The IMM internal LAN/USB IP address. The default value is 169.254.95.118.
imm_user_id
The IMM account (1 of 12 accounts). The default value is USERID.
imm_password
The IMM account password (1 of 12 accounts). The default value is PASSW0RD (with a
zero 0 not an O).
Note: If you do not specify any of these parameters, ASU will use the default values. When the
default values are used and ASU is unable to access the IMM using the online authenticated LAN
access method, ASU will automatically use the following unauthenticated KCS access method.
The following commands are examples of using the userid and password default values and not
using the default values:
Examples that do not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SYsInfoProdName <m/t_model>
user <imm_user_id> password <imm_password>
asu set SYSTEM_PROD_DATA.SYsInfoSerialNum <s/n> user <imm_user_id>
password <imm_password>
asu set SYSTEM_PROD_DATA.SYsEncloseAssetTag <asset_tag>
user <imm_user_id> password <imm_password>
Examples that do use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
v Online KCS access (unauthenticated and user restricted):
You do not need to specify a value for access_method when you use this access method.
The KCS access method uses the IPMI/KCS interface. This method requires that the IPMI driver be
installed. Some operating systems have the IPMI driver installed by default. ASU provides the
corresponding mapping layer. To see the Advanced Settings Utility Users Guide. You can access the
ASU Users Guide from the Lenovo support Web site.
172 ThinkServer ThinkServer RS210, Types 6531, 6532, 6533, and 6534: Hardware Maintenance Manual