Lightwave Communications LDX-3232 Power Supply User Manual


 
COMMAND REFERENCE
LDX-3232 Device-Dependent Command Reference
04_06 LDX-3232 81
CHAPTER 4
The TERM? query allows the programmer to determine whether the default
(IEEE488.2 standard) terminator has been altered to include a carriage return.
- where the response is 0 or 1.
Notes An altered terminator will be in the form <CR><NL><^END>. This termination will be
sent with all output until the "TERM 0" command is sent, or the LDX-3232 is powered off.
Examples "Term?" -response: 1, means that the <CR><NL><^END> terminator is temporarily
being used.
"Term?" -response: 0, means that the <NL><^END> terminator (GPIB/IEEE488
standard) is being used.
The TIME? query allows the programmer to determine how much time has passed since
the LDX-3232 was last powered up.
- where the response is character data in the form: hours:minutes:seconds.
Notes The TIME clock is independent of the TIMER clock.
Examples "Time?" -response: 1:02.36, means that one minute and 2.36 seconds have passed
since the LDX-3232 was powered up.
"TIME?" -response: 32:00:76, means that 32 minutes and 0.76 seconds have passed
since the LDX-3232 was powered up.
TERM?
FRONT PANEL
REMOTE
TIME?
FRONT PANEL
REMOTE
:
?TERM
:
?TIME