Mitsubishi Electronics CP900E Printer User Manual


 
16
CONNECTIONS
Press button.
RS232C menu is displayed.
Set BAUD RATE on this menu.
Press or button to select BAUD RATE.
The setting BAUD RATE (e.g. 1200) will be displayed.
Press or button to select 1200, 2400, 4800
or 9600 (bit/s).
Press or button to select COMMAND TYPE.
Press or button to select a , b or c .
Select a for normal setting. Depending on the connected equipment,
select b or c.
Press SET button.
SERVICE MENU is displayed.
SAVE is indicated.
Press or button to memorize the setting in prg.1,
prg.2 or prg.3.
Select CANCEL to cancel the setting.
Press SET button.
The source image (input signal from the equipment) is displayed.
The setting of BAUD RATE and COMMAND TYPE is
completed.
Set the communication format of the computer with a
computer connected.
Synchronizing system : Asynchronous communication
Data bit length : 8 bits
Parity bit : Nothing
Stop bit length : 1
Transmission order : Sent from LSB
Baud rate (bit/sec.) : 1200, 2400, 4800, 9600