Mitsubishi Electronics CP900E Printer User Manual


 
52
RS232C SET RS-232C signal setting display
This menu does not work when selecting THERMAL : ON or MULTI : OFF(PRN
SELECT).
BAUD RATE Set the baud rate of RS-232C.
Set the baud according to the connecting device.
COMMAND TYPE Sets the command type of RS-232C.
Selects the command type of RS-232C to control this unit.
Select A for normal setting. Depending on the connected equipment, select B
or C.
RESPONSE Selects whether this unit sends RS-232C response to the host
computer or not.
OFF Does not send response.
ON Sends normal response.
ERR RES OK Selects the response code when an error occurs.
NOR Sends the regular response.
ILL Sends job end even if ILLEGAL error occurs.
INV Sends job end even if INVALID error occurs.
ALL Sends job end when any error occurs.
NO DSR Sets to use 232C, DSR and DTR.
Sets NO DSR according to the connecting device.
OFF Uses NO DSR.
ON Does not use NO DSR.
RS232C SET
BAUD RATE 1200/2400/4800/9600
COMMAND TYPE A/B/C
RESPONSE OFF/ON
ERR RES OK NOR/ILL/INV/ALL
NO DSR OFF/ON
REMOTE SET Remote signal setting display
BUSY LEVEL Selects the level of BUSY signal from the remote terminals 1 and 2
on the rear panel.
LOW The VCP cannot accept the remote input signal when the signal is
LOW.
HIGH The VCP cannot accept the remote input signal when the signal is
HIGH.
The default setting is HIGH.
BUSY 1,2 SELECT Selects when the BUSY signal is outputted from the remote terminals
1 and 2 on the rear panel.
PRINTING Outputs BUSY signal during printing.
MECHA ERR Outputs BUSY signal when a mechanical error occurs in this unit or
IC chip is not installed. BUSY signal is also outputted when the printing
mechanism is pulled out or the menu is displayed on the monitor.
MEDIA ERR Outputs BUSY signal when an error for paper or ink sheet occurs.
MEMORY STOP Outputs BUSY signal when MEMORY button is not functioning.
STROBE 1V After outputting BUSY signal, memory is taken in by waiting to 1 vertical
period.
STROBE 2V After outputting BUSY signal, memory is taken in by waiting to 2 vertical
periods.
REMAINING Outputs BUSY signal while the remains of ink sheet becomes the
value set in REMAINING Qty.
When either STROBE 1V or STROBE 2V is set to OFF, the other is available for
setting.
REMOTE SET
BUSY LEVEL LOW/HIGH
BUSY1,2 SELECT
PRINTING
OFF/1/2/1&2
MECHA ERR
OFF/1/2/1&2
MEDIA ERR
OFF/1/2/1&2
MEMORY STOP
OFF/1/2/1&2
STROBE 1V OFF/1/2/1&2
STROBE 2V OFF/1/2/1&2
REMAINING
OFF/1/2/1&2
ADJUSTMENTS & SETTINGS (SERVICE MENU)