Mitsubishi Electronics CP900E Printer User Manual


 
33
CONNECTIONS
PRINTING
ADJUSTMENTS
PRECAUTIONS FEATURES
PREPARATION
OTHERS
TROUBLE-
SHOOTING
PIN NO. REMOTE TERMINAL
By sending the following remote control codes from pin No.6, the same functions as the wired
remote control unit supplied can be controlled.
01: button 02: button 03: button 04: button
08: PRINT Qty button 09*
0A*: MENU button 0B*: CLEAR button 0C: PRINT Qty button
0D* 0E*: SET button 0F*: STOP button
12*: PROGRAM button 13*: PRINT button 15*: FIELD/FRAME button
16*: COLOR ADJ button 17*: MEMORY button 18*: DISPLAY button
1C*: MEMORY PAGE button 1D*: MONITOR button
In case of the codes with * mark, 5 words are sent.
TIMING CHART
Input signal level : TTL
Input timing : 1 word 38.4 ms (Reference)
T
1
>
0.4 ms
1.5 ms < T
2
< 2 ms
2 ms < T
3
< 4.2 ms
13 ms < T
4
< 90 ms
(EXAMPLE) Print code
= 13 = 0 1 0 0 1 1
1.6 ms (T
2
)
0.4 ms
(T
1
)
3.2 ms(T
3
)
0.4 ms (T
1
)
110010
T
4
1 word
(The above values are references.)