α
2 Simple Application Controllers
Remote Access 3
3 - 9
Note:
The 3COM (SP560-V), OMRON (ME3314) and AIWA (PV-AF3360) standard modems have
been used as the default modem for the
α
2 Series Controller, however, if the user has installed
a standard modem of their choice with a different AT command then additional AT commands
can be included.
Having installed VLS to the Program files directory.
C:\Program Files\Alvls\BIN
please choose the Modem.ini file that contains AT information for standard modem selection in
VLS.
Contents of the Modem.ini file:
; This is Modem.ini File, used to Display Modem Models
; and their Initialization commands. This file is used
; while Initializing the Controller Modem.
;
; Please add any new Modem models and Initializing commands
; only at the end of the file. An example is given below:
;
; 1="USRoboticsXXX","AT&F"
; Here "1" is serial number in increasing order
; "USRoboticsXXX" is modem model
; "AT&F" is the initializing command (Max 64 Chars).
;
[Modem]
1="New",""
2="3COM SP560V-P","ATE0Q1&B1&D0&H0&I0&R1&S0S0=2S15=8&W"
3="OMRON ME3314","ATE0S0=2Q1&D0S15=8&R1&H0&W"
4="AIWA PV-AF3360","ATE0S0=2Q1&D0&M5\Q0\J0&W"
Simply follow the instruction listed above, subsequentially, the additional standard modems will
be included with attached AT command string.