Moxa Technologies NE-4100 Network Card User Manual


 
NE-4100 Series User’s Manual Serial Command Mode
9-7
OP Code Parameter Comments
CY
ASCII character in hex code
(i.e., “A1” for character 0xA1)
character to use for delimiter 1
CZ
ASCII character in hex code
(i.e., “A1” for character 0xA1)
character to use for delimiter 2
CF 0 – 65535 (ms) force transmit time
UDP Mode
OP Code Parameter Comments
UL 0 – 65535 local listen port
UA
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 1, begin range
UB
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 2, begin range
UC
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 3, begin range
UD
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 4, begin range
Ua
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 1, end range
Ub
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 2, end range
Uc
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 3, end range
Ud
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 4, end range
U1 0 – 65535 destination IP address 1, port
U2 0 – 65535 destination IP address 2, port
U3 0 – 65535 destination IP address 3, port
U4 0 – 65535 destination IP address 4, port
UX
0: no delimiter
1: enable 1-character delimiter
2: enable 2 character delimiter
number of characters to use as delimiter
UY
ASCII character in hex code
(i.e., “A1” for character 0xA1)
character to use for delimiter 1
UZ
ASCII character in hex code
(i.e., “A1” for character 0xA1)
character to use for delimiter 2
UF 0 – 65535 (ms) force transmit time