Moxa Technologies NE-4100 Network Card User Manual


 
NE-4100 Series User’s Manual Serial Command Mode
9-14
Entering Serial Command Mode
Trigger Type
The module can enter serial command mode through either a hardware trigger or a software trigger,
depending on how it has been configured. Please refer to the previous section for details on how to
configure the trigger type.
Hardware Trigger
z Set up a hardware trigger with the DIO 0 channel.
z Use the trigger to pull DIO 0 to low in order to enter serial command mode. Low state must
be maintained for at least 200 ms to qualify as a valid trigger.
Software Trigger
z Define 3 characters as the software trigger.
z Send the 3 trigger characters to the serial port in rapid sequence (less than 20 ms between
characters) in order to enter serial command mode.
Serial Port Parameters
For testing purposes, you will likely use a terminal emulator to send and receive data frames in
serial command mode. The module’s serial parameters may be obtained from Network Enabler
Administrator, or from the web or Telnet consoles. For example, from Network Enabler
Administrator, the settings may be found in the Configuration functions by selecting Configure
and then selecting the Serial tab. After selecting the module’s serial port, click on Settings to open
the Serial Settings window.