Moxa Technologies NE-4100 Network Card User Manual


 
NE-4100 Series User’s Manual Web Console Configuration
6-8
z Install Network Enabler Administrator and use the built-in IP Address Report function.
z Develop software that parses the IP address report data. Please refer to Appendix C for details
on how to parse the module’s IP address report data.
Auto report to IP
Setting Factory Default Necessity
E.g., 192.168.1.1 or URL
(IP addresses of the form x.x.x.0 and
x.x.x.255 are invalid.)
None Optional
If left blank, auto IP reporting is disabled. If an IP address is entered along with a TCP port
number, the IP address reports will be sent to the specified address and port number.
Auto report to TCP port
Setting Factory Default Necessity
E.g., 4001 4002 Optional
If left blank, auto IP reporting is disabled. If a TCP port number is entered along with an IP
address, the IP address reports will be sent to the specified address and port number.
Auto report period
Setting Factory Default Necessity
Time interval (in seconds) 10 Optional
The Auto report period field specifies how often the module will report its IP address. An auto
report period of 10 seconds means that an IP address report will be sent every 10 seconds.
ATTENTION
The module will send IP address reports only when assigned an IP address from a DHCP or
BOOTP server. If a connection to a DHCP or BOOTP server is not available, no IP address report
will be sent..
Serial Settings
Note: “Serial Command Mode” is supported in firmware version 3.0 and above.