Moxa Technologies NE-4100 Network Card User Manual


 
NE-4100 Series User’s Manual Web Console Configuration
6-22
SNMP trap server
SNMP trap server IP or domain name
Setting Factory Default Necessity
IP or Domain Name None Optional
Event Type
Note: “Serial Command Mode” is supported in firmware version 3.0 and above.
On the Event Type page, you may configure how administrators are notified of certain system,
network, and configuration events. Depending on the event, different options for automatic
notification are available, as shown above. Mail refers to sending an e-mail to a specified address.
Trap refers to sending an SNMP trap. The following items are events that can trigger an automatic
warning.
Cold start
The module is started from a power off state. If this is selected, automatic notification is sent if the
module is powered off and then powered on again.
Warm start
The module is restarted without turning the power off. If this is selected, automatic notification is
sent if the module is rebooted while still powered on.
Authentication failure
The user inputs a wrong password from the console or Network Enabler Administrator. If this is
selected, automatic notification is sent if a user attempts to unlock the module and enters the
wrong password.
IP address changed
The module’s IP address has been changed. If this is selected, the module will attempt to send an
e-mail before it reboots with a new IP address. If the module fails to reach the mail server after 15
seconds, it will reboot anyways and no notification will be sent.
Password changed
The module’s password has been changed. If this is selected, the module will attempt to send an
e-mail before it reboots with a new password. If the module fails to reach the mail server after 15
seconds, it will reboot anyways and no notification will be sent.