Moxa Technologies NE-4100 Network Card User Manual


 
NE-4100 Series User’s Manual Web Console Configuration
6-15
TCP Client Mode
Note: “Serial Command Mode” is supported in firmware version 3.0 and above.
TCP alive check time
Setting Factory Default Necessity
0 to 99 min 7 min Optional
0 min: The TCP connection is not closed due to an idle TCP connection.
1 to 99 min: The module automatically closes the TCP connection if there is no TCP activity for
the given time. After the connection is closed, the module starts listening for another host’s TCP
connection.
Inactivity time
Setting Factory Default Necessity
0 to 65535 ms 0 ms Optional
0 ms: The TCP connection is not closed due to an idle serial line.
0-65535 ms: The module automatically closes the TCP connection if there is no serial data activity
for the given time. After the connection is closed, the module starts listening for another host’s
TCP connection.
This parameter defines the maintenance status as Closed or Listen on the TCP connection. The
connection is closed if there is no incoming or outgoing data through the serial port during the
specific Inactivity time.
If Inactivity time is set to 0, the current TCP connection is maintained until there is a connection
close request. Even with Inactivity time is disabled, the module will still check the connection
status between itself and the remote host by sending “keep alive” packets periodically. If the
remote host does not respond to the packet, it assumes that the connection was closed down
unintentionally. The module will then force the existing TCP connection to close.