Moxa Technologies NE-4100 Network Card User Manual


 
NE-4100 Series User’s Manual Serial Command Mode
9-15
Comments
When first entering serial command mode, the module will respond with the string “<E” + CR. All
data communication will cease when the device is in serial command mode.
z Any open TCP connection will be closed, for both the client and the server.
z No new TCP connections will be allowed.
z UDP data communication will be disabled.
Exiting Serial Command Mode
After the module has entered serial command mode, there are three ways to exit.
z Power Off
If the module is powered off without saving the configuration, all changes will be lost when
the module is powered on again.
z Exit by Command (OP Code: BR)
There are two options when manually exiting by serial command. Save & Restart must be
selected if you want to save any of the changes that were made during the serial command
mode session. Restart will restart the module without saving any of the changes.
z Auto Restart
If 5 minutes elapses without inputting a valid command, then the module will automatically
restart without saving the configuration.