NETGEAR 7300 Series Switch User Manual


 
User Manual for the NETGEAR 7300 Series Layer 3 Managed Switch Software
8-54 Switching Commands
202-10009-01_060204
Format show garp
Mode Privileged EXEC and User EXEC
GMRP Admin Mode This displays the administrative mode of GARP Multicast Regis-
tration Protocol (GMRP) for the system.
GVRP Admin Mode This displays the administrative mode of GARP VLAN Registra-
tion Protocol (GVRP) for the system.
show gmrp configuration
This command displays Generic Attributes Registration Protocol (GARP) information for one or
all interfaces.
Format
show gmrp configuration {<slot/port> | all}
Mode Privileged EXEC and User EXEC
Interface This displays the slot/port of the interface that this row in the
table describes.
Join Timer Specifies the interval between the transmission of GARP PDUs
registering (or re-registering) membership for an attribute. Cur-
rent attributes are a VLAN or multicast group. There is an
instance of this timer on a per-Port, per-GARP participant basis.
Permissible values are 10 to 100 centiseconds (0.1 to 1.0 sec-
onds). The factory default is 20 centiseconds (0.2 seconds). The
finest granularity of specification is 1 centisecond (0.01 seconds).
Leave Timer Specifies the period of time to wait after receiving an unregister
request for an attribute before deleting the attribute. Current
attributes are a VLAN or multicast group. This may be consid-
ered a buffer time for another station to assert registration for the
same attribute in order to maintain uninterrupted service. There is
an instance of this timer on a per-Port, per-GARP participant
basis. Permissible values are 20 to 600 centiseconds (0.2 to 6.0
seconds). The factory default is 60 centiseconds (0.6 seconds).
The finest granularity of specification is 1 centisecond (0.01 sec-
onds).
LeaveAll Timer This Leave All Time controls how frequently LeaveAll PDUs are
generated. A LeaveAll PDU indicates that all registrations will
shortly be deregistered. Participants will need to rejoin in order to
maintain registration. There is an instance of this timer on a per-