NETGEAR 7300 Series Switch User Manual


 
User Manual for the NETGEAR 7300 Series Layer 3 Managed Switch Software
Switching Commands 8-55
202-10009-01_060204
Port, per-GARP participant basis. The Leave All Period Timer is
set to a random value in the range of LeaveAllTime to
1.5*LeaveAllTime. Permissible values are 200 to 6000 centisec-
onds (2 to 60 seconds). The factory default is 1000 centiseconds
(10 seconds). The finest granularity of specification is 1 centisec-
ond (0.01 seconds).
Port GMRP Mode Indicates the GMRP administrative mode for the port. It may be
enabled or disabled. If this parameter is disabled, Join Time,
Leave Time and Leave All Time have no effect. The factory
default is disabled.
Port GVRP Mode Indicates the GVRP administrative mode for the port. It may be
enabled or disabled. If this parameter is disabled, Join Time,
Leave Time and Leave All Time have no effect. The factory
default is disabled.
show gvrp configuration
This command displays Generic Attributes Registration Protocol (GARP) information for one or
all interfaces.
Format
show gvrp configuration {<slot/port> | all}
Mode Privileged EXEC and User EXEC
Interface This displays the slot/port of the interface that this row in the
table describes.
Join Timer Specifies the interval between the transmission of GARP PDUs
registering (or re-registering) membership for an attribute. Cur-
rent attributes are a VLAN or multicast group. There is an
instance of this timer on a per-Port, per-GARP participant basis.
Permissible values are 10 to 100 centiseconds (0.1 to 1.0 sec-
onds). The factory default is 20 centiseconds (0.2 seconds). The
finest granularity of specification is 1 centisecond (0.01 seconds).
Leave Timer Specifies the period of time to wait after receiving an unregister
request for an attribute before deleting the attribute. Current
attributes are a VLAN or multicast group. This may be consid-
ered a buffer time for another station to assert registration for the
same attribute in order to maintain uninterrupted service. There is
an instance of this timer on a per-Port, per-GARP participant
basis. Permissible values are 20 to 600 centiseconds (0.2 to 6.0