Nortech Systems XUSR Switch User Manual


 
Configuring a Single sDIO
Adept SmartController User’s Guide, Rev. E 99
5. Type N at the following prompt.
Attached controller 0. Change this value?
Then, press ENTER to continue.
6. Type Y at the following prompt.
Digital input block: 16 Change this value?
Then, press ENTER to continue.
7. Enter a new value for the input block at the following prompt.
Enter new value:
Then, press ENTER to continue.
8. Type Y at the following prompt.
Digital output block: 16 Change this value?
Then, press ENTER to continue.
9. Enter a new value for the output block number at the following prompt.
Enter new value:
Then, press ENTER to continue.
10. Type Y at the final prompt.
Do you want to save these changes?
Then, press ENTER to continue.
After selecting block numbers, you must assign groups of signal numbers to each block.
NOTE: You must select a unique block number for the Inputs and Outputs
of each sDIO in your system. Repeat the procedure above for each sDIO.
Assigning I/O Signal Numbers
The I/O signal number ranges are valid for the sDIO:
Inputs 1033 to 1512
Outputs 0033 to 0512
You will need to perform the follow steps to assign I/O signals to specific blocks, if you
choose a block other than 16.
1. Load and Execute the CONFIG_C.V2 utility.
2. Select option 2.
2 - V+ System Configuration Data
Then, press ENTER to continue.