Promise Technology NS2300N Network Card User Manual


 
Chapter 7: Troubleshooting
131
Checking Enclosure Status in PASM
To check Enclosure status:
1. Start PASM.
See “PASM in your Browser” on page 80.
Or see “PASM in SmartNAVI” on page 81.
2. In the Tree, click the + beside the System icon.
3. Click the System Information icon.
4. Click the Enclosure Information tab.
Migration or Rebuilding
on array X aborted at Y%
RAID Volume Migration or Rebuild was aborted
(stopped) by user action.
Migration or Rebuilding
on array X aborted at Y%
because of error.
RAID Volume Migration or Rebuild has aborted
(stopped) because of an error. Check the disk drives.
See page 124. Check the RAID Volume. See
page 125.
RAID status: "OFFLINE".
The NS2300N X volume
Y is offline.
Check the disk drives. See page 124. Replace the
failed drive. See page 124. Create a new RAID
Volume. See page 101.
RAID status: "CRITICAL".
The NS2300N X volume
Y is not functioning
correctly.
Check the disk drives. See page 124. Replace the
failed drive. See page 124. The RAID Volume will
rebuild automatically.
RAID X had some errors.
Formatting was aborted!
Check the disk drives. See page 124. Replace the
failed drive. See page 124.
Reported Event Corrective Action