Q-Logic 8C/16 Switch User Manual


 
A Command Line Interface
Set Config Command
A-28 59022-04 B
threshold
Initiates a configuration session by which to generate and log alarms for selected
events. The system displays each event, its thresholds, and sampling interval one
line at a time and prompts you for a value. For each parameter, enter a new value
or press the Enter key to accept the current value shown in brackets. These
parameters must be saved in a configuration and activated before they will take
effect. Refer to the Config Command on page A-7 for information about saving
and activating a configuration. Table A-9 describes the Set Config Threshold
parameters.
PrincipalPriority The priority used in the FC-SW-2
principal switch selection algorithm. 1 is
high, 255 is low.
ConfigDescription The name for the configuration. The
default is undefined.
Table A-9. Set Config Threshold Parameters
Parameter Description
Threshold Monitoring Enabled Master enable/disable parameter for all
events. Enables (True) or disables (False)
the generation of all enabled event alarms.
CRCErrorsMonitoringEnabled
DecodeErrorsMonitoringEnabled
ISLMonitoringEnabled
LoginMonitoringEnabled
LogoutMonitoringEnabled
LOSMonitoringEnabled
The event type enable/disable parameter.
Enables (True) or disables (False) the
generation of alarms for each of the
following events:
CRC errors
Decode errors
ISL connection count
Login errors
Logout errors
Loss-of-signal errors
Rising Trigger The event count above which an event is
logged. Once the count exceeds the rising
threshold, one alarm is logged. The switch
will not generate another alarm for that
event until the count falls below the falling
threshold and rises again above the rising
threshold.
Table A-8. Set Config Switch Parameters
Parameter Description