HCD-E1 Installation & Operation Manual Chapter 4 - Control from the Supervisory Port
11/01/00 19:23 HCD-E1 Command Set Description 4-35
INTERVAL 01 ES = 000 UAS = 000 SES = 000 BBE = 000
ESR = 00.00% SESR = 00.00% BBER = 00.00%
INTERVAL 02 ES = 000 UAS = 000 SES = 000 BBE = 000
ESR = 00.00% SESR = 00.00% BBER = 00.00%
INTERVAL 03 ES = 000 UAS = 000 SES = 000 BBE = 000
ESR = 00.00% SESR = 00.00% BBER = 00.00%
INTERVAL 04 ES = 000 UAS = 025 SES = 026 BBE = 001
ESR = 00.00% SESR = 02.88% BBER = 00.11%
24 HOUR ES = 0
24 HOUR UAS = 25
24 HOUR SES = 26
24 HOUR BBE = 1
24 INTERVAL = 04
DSP PB
Purpose
Display the priority bumping of time slots selected by the user.
Syntax
DSP PB <CR>
Use
To display the priority bumping of time slots, type:
DSP PB<CR>
A typical display is shown below:
TIME SLOT MAPPING OF PRIORITY BUMPING
=====================================
TS: 0123456789
PRIORITY: HIGH LOW LOW LOW LOW LOW LOW LOW LOW LOW
TS: 10 11 12 13 14 15 16 17 18 19
PRIORITY: LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW
TS: 20 21 22 23 24 25 26 27 28 29
PRIORITY: LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW
TS: 30 31
TYPE: LOW LOW
Note
This command would show correct information only when one of the lines is
down