HCD-E1 Installation & Operation Manual Chapter 5 - Troubleshooting and Diagnostics
01/01/01 08:15 Configuration Error Messages 5-33
Table 5-5 Configuration Error Messages (Cont.)
Error Code Terminal Message and Description
ERROR 17 TS 0 IS MAPPED TO G732N FRAME TYPE
You are trying to assign TS 0 for the G732N frame type
ERROR 18 Reserved for future use.
ERROR 19 ILLEGAL PARAMETER FOR CURRENT CONFIGURATION
You are using a parameter which is not supported by this HCD-E1 version or
configuration.
ERROR 20 LOOP IS ACTIVE, CAN’T UPDATE HARDWARE
When a test or loopback is active, it is not possible to change the HCD-E1 operating
mode in accordance with the updated configuration parameters. You may see this
message either after pressing ENTER, or after an update data base command has been
received through the supervisory port (or in-band management). You must first
deactivate the test or loopback.
ERROR 21 CAN’T PERFORM LOOP - CHANNEL NOT CONNECTED
The channel on which you are trying to perform a loop has no time slots assigned to it.
ERROR 22 CAN’T PERFORM LOOP - PORT NOT CONNECTED
You are trying to activate a loopback on an E1 sublink which is not connected (no E1
time slots are mapped to HDSL frame).
ERROR 23 CAN’T DISCONNECT - LOOP IS ACTIVE
You are trying to disconnect a channel while a loop on this channel is currently active.
ERROR 24 CURRENT LOOP IS ALREADY BEING PERFORMED
You are trying to perform a loop which is currently active.
ERROR 25 ILLEGAL COMMAND, LINK IN UNFRAMED MODE
You are trying to set time slot priority bumping while the link is in unframed mode.
ERROR 26* CHANNEL BERT LOOP IS NOT ACTIVE
You are trying to activate the DSP BERT CH command, while the channel BERT test is
not active.
ERROR 27* YEAR SHOULD BE IN THE RANGE 1996-2095
You are trying to select an invalid number for the year.
ERROR 28* ILLEGAL DCD_DEL AND INTERFACE COMBINATION
You are trying to select a non-zero DCD DELAY, while the HCD-E1 supervisory port
interface has been set as DCE.
ERROR 29* CONFLICT IN INTERFACE AND DSR PARAMETERS
You selected DSR=ON, while the supervisory port interface has been set to DTE. The
DSR=ON selection is valid only for DCE interface.