RAD Data comm HCD-E1 Modem User Manual


 
HCD-E1 Installation & Operation Manual Chapter 2 - Installation and Setup
11/12/00 10:36 Installation and Setup 2-3
Jumper C/R
Central
Unit
Remote
Unit
JP4
R
J10
/C
C
R
C
R
FGND/GND
ON
OFF
JP8
ON
OFF
Not
Connected
Connected
FGND/GND
ON
SPARE
PASSWD
DEF SP
DB INIT
S1
Sublink
Interface Board
Data Channel 2
Interface Board
RJ-45
Connector
Figure 2-1 HCD-E1 - Identification of Boards, Jumpers and Switches
The Main Board contains the common signal processing circuits, the
interfaces to the main link (HDSL) and the Data Channel 1 interface. A DIP
switch unit (S1) and two jumpers (JP4 and JP8) are provided for user settings.
The board contains additional jumpers which are factory-set and should not
be changed by the user.
The Data Channel 2 Interface Board provides the connections of data
channel 2. The board does not have any user-set jumpers or switches
(except for the Ethernet board, see Appendix C and Appendix D).
The E1 Sublink Interface Board provides the E1 connections and contains
several user-set jumpers.
To set the internal jumpers and switches, you must do the following in this
order:
Open the HCD-E1 case
Set the Main Board Jumpers and Switch, referring to Figure 2-1.
Remove the E1 Sublink Internal Board, if it is necessary to modify its
settings.
Identify jumper and switch locations and settings on the Sublink Interface
Board (referring to Figure 2-4) and change settings as required.
Reinstall the E1 Sublink Interface Board, if it has been removed.
Reinstall the HCD-E1 cover.