RAD Data comm HCD-E1 Modem User Manual


 
Chapter 4 - Control from the Supervisory Port HCD-E1
Installation & Operation Manual
4-10 HCD-E1 Control Language 11/01/00 19:23
Table 4-1 HCD-E1 Command Set Index (Cont.)
Command Purpose Options
CLR ALM HRPT Clear the ON-type alarms stored in the H-RPT alarm buffer /A
CLR LOOP BERT CH X, or
CLR LP BERT CH X*
CLR LOOP INBAND CH X,
or CLR LP INBAND CH X*
CLR LOOP L HRPT, or
CLR LP L HRPT
CLR LOOP L LINE, or
CLR LP L LINE
CLR LOOP L CH X, or
CLR LP L CH X*
CLR LOOP R CH X, or
CLR LP R CH X*
CLR LOOP R R CH X, or
CLR LP R R CH X*
CLR LOOP L SL, or
CLR LP L SL
CLR LOOP R SL, or
CLR LP R SL
CLR LOOP R R SL, or
CLR LP R R SL
Deactivate the BERT test on data channel X of the remote unit
Deactivate the in-band loopback on data channel X of HCD-E1
Deactivate a local loop on H-RPT (only for HCD-E1 configured as
central)
Deactivate a local (L) loopback on the HDSL lines
Deactivate the local (L) loopback on data channel X of local HCD-E1
Deactivate the remote (R) loopback on data channel X of local
HCD-E1
Deactivate the remote (R) loopback on data channel X of the remote
unit
Deactivate a local (L) loopback on the E1 sublink of the local HCD-E1
Deactivate the remote (R) loopback on the E1 sublink of the local
HCD-E1
Deactivate a remote (R) loopback on the E1 sublink of the remote
unit
CLR TST Clear all the user-initiated tests and loopbacks
DATE Set the internal date for HCD-E1
DEF AGENT Define the parameters of the internal SNMP agent of HCD-E1
DEF BERT CH 1
DEF BERT CH 2
Define the type of test sequence, set the error injection rate to be
used for BER testing on the corresponding channel, and control the
receipt of the activation pattern for the in-band loopback initiation.
DEF CH 1
DEF CH 2
Configure the parameters of the corresponding channel
DEF DL Define the E1 sublink and main link in-band management
parameters
DEF NAME Define the logical name of HCD-E1
DEF NODE Define the node number of HCD-E1
DEF PB Define the time slot mapping of priority bumping
DEF PWD Define a password
DEF SL Define E1 sublink parameters
DEF SP Define control port parameters
DEF SYS Define system parameters
DEF TERM Reset the terminal control codes to 0