Chapter 5 Hardware Functional Descriptions 5-13
H8 interface providing IPMC support.
MPC interface.
SSI Interface (UltraSPARC T2).
BUS Interface and Arbiter (Round Robin).
Bus Clock Control
Power sequence control of DC/DCs on board.
Interrupts.
Data Channel/Fast Mailbox Control.
The FPGA configuration is performed after an FPGA reset when the configuration is
downloaded from the PROM.
5.2.8 Intelligent Platform Management Controller
The Renesas H8S/2166 provides the IPM controller (IPMC) function on the Netra
CP3260 blade server. The IPMC provides PICMG 3.0 blade server management
functionality, and it interfaces to the host CPU through a serial interface. The IPMC
subsystem is powered from the standby power.
The IPMC is responsible for the following:
Dual-buffered IPMB interfaces to connect to IPMB-0
Serial payload interface to the host through PPC
IPMI_L interface to communicate with MMC on ARTMs
Power control of the entire Netra CP3260 blade server
Power and reset control of the AMC board
Hot-swap latch input and LED control
Power control
E-Keying control