B-1
APPENDIX
B
Sun OEM IPMI Commands
This appendix contains the following sections:
■ Section B.1, “Get Version Command” on page B-2
■ Section B.2, “Get RTM Status Command” on page B-3
■ Section B.3, “Solaris OS Graceful Shutdown Commands” on page B-4
■ Section B.4, “Send Sensor State Command” on page B-5
The commands described in this appendix are specific to Netra CP3260 blade server
designed by Sun Microsystems. The Internet Assigned Numbers Authority (IANA)
number assigned to Sun Microsystems is 42.
Refer to http://www.iana.org/assignments/enterprise-numbers for more
information about IANA number assignments.
The netfunction (NetFn) used for these commands is 0x2E, which is the OEM
netfunction as defined in the IPMI specification. For this netfunction, the first three
data bytes in the request packet must be this IANA number and the first three bytes
in the response packet following the completion code are the IANA number. For Sun
ATCA node boards, these three bytes are 00 00 2A.