Installation
1760 Series Component Waveform/Vector Monitor User Manual
1-11
WARNING
When power is supplied, line voltage will be
present in the instrument, even if the POWER
switch is set to STANDBY.
Mains Frequency and Voltage Range
The 1760--Series m onitors operate a t 50 and 60 Hz, over the
range of 90--250 Volts, without operator adjustment.
Remote Connector
The rear-panel REMOTE connector is a 25-pin, D-type connec-
tor. It provides the input for
RGB/YRGB staircase, external
horizontal, and remote sync. For more information about the
remote connector, see page 2-8 and page B-1.
RS232 Connector
The rear-panel RS232 connector is a 9-pin subminiature D-
type connector that provides a serial interface for remote
control. The RS232 pin assignments are on page B-1.
Operational Changes
No operational modifications a re m ade to these monitors
through internal jumper settings. Input coupling,
DC RE-
STORER
clamp time, RGB/YRGB selections and other similar
configurations are changed through the on-screen menu.
Instrument configuration is described on pa ge 3-20.