1760 Series Component Waveform/Vector Monitor User Manual 2-11
Operator’s Checkout
Procedure
Before proceeding, read At A Glance startingonpage2-1.
This procedure is designed for operator familiarization and
for checking basic instrument operation (not measurement
quantities or specifications). All illustrations are of the 1765
unless otherwise noted.
If performing this procedure reveals improper instrument
operation, first check the operation of the associated equip-
ment. If t he associated equipment is operating normally,
refer the 1760--Series to qualified service personnel for
repair or adjustment.
Required Equipment
The following equipment is required to perform this proce-
dure:
1. Te levision Signal Generator with:
Composite Color Bars
Component signal (Y, B--Y, R--Y)
Channel Timing (Bowtie)
Black Burst or comparable signal with burst and sync.
For example: TEKTRONIX TSG 130--Series Multifor-
mat Signal Generator
2. Coaxial Cable, 75Ω (5)
For example: 42-inch RG59U (Tektronix Part No.
012-0159-00)
3. 75Ω Terminators, End- line (4)
For example: (Te ktronix Part No. 011-0102-00)