Operator’s Checkout Procedure
1760 Series Component Waveform/Vector Monitor User Manual
2-22
9. Line Selection
Line select is available in
WAVEFORM, VECTOR, SCH,and
PICTURE display modes. Enter the LINE SELECT menu and
turn the center bezel control until the readout displays
ALL
131
. In a two line display, line 131 appears on the left,
followed by line 132.
Select
2FIELDsweep and note the intensified line in each
field. Select
15H and note that 15 lines are now intensified
in each field (intensified portion appears wider). The
readout is now
ALL 131---- 145. See Figure 2-13.
Select
1of2. Now only the first field has intensified lines,
and a
NEXT FIELD selection appears. Select NEXT FIELD and
note that the intensified lines now appear only in the second
field and the readout is
F2 131 F2 145.
Select MULTIPLE with WAVEFORM, VECTOR, and SCH. Note
that the displays appear in the following order:
WAVEFORM,
VECTOR, SCH.
Exit the line select menu. Enter the menu again and note
that the user settings are unchanged. Exit the menu.
LINE SEL
ALL131
FIELD
ALL 1OF2
1OF81OF4
1H
15H
-- -- 1 4 5
Figure 2-13. Line Select display with 15H selected, in 2 FIELD sweep.