Tektronix 1760 Computer Monitor User Manual


 
1760 Series Component Waveform/Vector Monitor User Manual 3-1
Functional Overview
The Functional Overview describes instrument functions in
greater detail than At A Glance. For menu operation, refer to
page 3-7. Detailed Measurement procedures are given in
Basic Measurements, beginning on page 4-1.
Display Modes Composite C omponent
H VECTOR ••
H SCH (Option SC only)
H WAVEFORM ••
H AUDIO ••
H LIGHTNING and DIAMOND
H BOWTIE
H PICTURE ••
H TIME CODE ••
H MULTIPLE displays ••
Vector
The vector mode presents an XY plot of demodulated chromi-
nance phase and amplitude. The angle represents chromi-
nance phase and the distance from the center represents
chrominance amplitude. A bezel control is assigned to adjust
VECTOR PHASE.
With a component input (A123 or B123), VECTOR displays
CH-3 (typically R--Y or P
R
) versus CH-2 (typically B--Y or
P
B
).