Using the Menus
1760 Series Component Waveform/Vector Monitor User Manual
3-13
Vector + Waveform (Multiple)
If MULTIPLE is pressed and both VECTOR and WAVEFORM dis-
plays are selected, menus for all cursor types will be dis-
played. See Figure 3-4. All cursor functions are available in
this mode (the top three bezel buttons are self-cancelling).
Bezel control assignments are the same as for the individual
modes.
Using the Cursors
With Vector Display
To use vector cursors, operate in VECTOR or VECTOR+WAVE-
FORM
mode and press the CURSOR MENU button. There are
two vector cursor displays:
POLAR and MARK. (The VECTOR
PHASE
bezel control continues to adjust the phase of the sig-
nal
.)
Polar Cursors can be used to measure the amplitude and
phase of the chrominance signal. When
POLAR is selected,
position the cursor (cross hairs) with the
AMPLITUDE and
PHASE bezel controls, and view the amplitude and phase
readouts at the top of the screen. See Figure 3-2. When a
component signal is displayed (A 1-2-3 or B 1-2-3), it will be
encoded so that the readout phase and amplitude matches
that of a composite signal. This feature allows the operator
to set component equipment to a specific color phase if the
composite phase value is known.
The cursor zero amplitude point is the center point of the
graticule. Using the amplitude control to move the cursor
out from the center increases the amplitude. Adjusti ng the
cursor phase will rotate the cursor around the center point,
with the zero phase point being the B--Y (U) axis. The am-
plitude readout can be set for m
V or IRE values through the
CONFIG menu, described on page 3-20.