#J1 Check V.42 compatibility
#K0 Disable MNP 10
#K1 Enable MNP 10
#K2 Enable MNP 10 with cellular
options
#M0 command operation
#M1 Asynchronous V.25bis
#M2 Synchronous V.25bis (HDLC
framing)
#M3 Synchronous V.25bis (Char.
framing-BSC mode)
#N0 NRZ Character Encoding
#N1 NRZI Character Encoding
#O0 Characters are ignored if the
modem buffers overflow.
#O1 Modem disconnects if the terminal
buffer overflows.
#O2 Modem disconnects if the line
buffer overflows.
#O3 Modem disconnects if either buffer
overflows.
#Q V.25bis Terminal Speed
#Q0 Use last autobaud speed
#R Enable remote control mode
#S Display Security Menu
#U V.25bis Character Set
#U0 ASCII character set
#U1 EBCDIC character set
#V0 Command and S Register verifier
off
#V1 Command and S Register verifier on
%B0 S0=0 No AutoAnswer
%B2 S0=2 Modem answers after two
rings
%C0 Compression disabled
%C1 MNP 5 compression enabled
%C2 V.42bis data comression enabled
%C3 V.42bis data compression enabled
with fallback to MNP 5
%D0 No disconnect delay
%E0 Auto EQM Retrain OFF
%E1 Auto EQM Retrain ON
%E2 V34/V32 auto rate change
%F0 A & B switches control V.25bis
function
%F1 Switch A forces DTR on, Switch B
forces DSR high
%H0 Use the B setting for initial MNP
10 connection speed. The B setting
is the maximum speed.
%H1 Initial connection speed is made at
1200 bps (V.22). The maximum
speed is defined by the B setting.
%H2 Initial connection made at 4800
bps (V.32). The maximum speed is
limited by the B setting.
%H3 Initial connection made at 9600
bps (V.32). The maximum speed is
limited by the B setting.
%H9 Use the B setting for the initial
connection speed, but do not
upshift until the connection is
established. (Telenetics modems
only).
%K0 CTS operates normally
%K1 CTS is lowered when an D
command is issued and remains low
until a connection is established
%L Display Line Signal Level 11-19
(13 default) -11dB-19dB transmit
level
%M0 Mode LEDs indicate the
connection speed
%M1 Mode LEDs indicate the line
quality, V.42/MNP errors and flow
control
%N0 Standard Baud Rates
%N1 Standard to 14400 then 20800,
31200, 41600 and 62400
%N2 Standard to 38400 then 51200
%P0 CONNECT message appears before
DCD is asserted
%P1 CONNECT message appears after
to DCD is asserted
%Q Display line signal quality
%R0 &R command determines the state
of CTS
%R1 CTS always follows RTS (both in
on-line state and local command
state)
%R2 V.25bis mode: CTS on when ready
to accept a command
%S0 DSR is not overridden
%S1 DSR mimics the state of the DTR
signal (only reset by &F.)
%T0 DCD always follows the state of the
carrier from the remote modem