Setup: Calibrating the Touchscreen 9.19
At any time while using the tabs to view system details, the touchscreen can be calibrated by executing
the built-in calibration routine.
To calibrate the touchscreen:
Press the
Setup
Tab.
Press the
DISP-EX 800
button
Press the entry
Cali
to begin the calibration
routine
Follow the directions on the display to press
the “+” at each location it flashes on the
display.
To exit the calibration routine press QUIT at
any time. (See Figure 9-16.)
After the touchscreen has been recalibrated,
the display will indicate that the
calibration routine has passed.
Press Quit to return to the main display. (See
Figure 9-16 - C.)
Figure 9-16 Touch Screen Calibration