Toshiba MR-3018 Scanner User Manual


 
June 2005 © TOSHIBA TEC MR-3018 DISASSEMBLY AND ASSEMBLY
4 - 19
4
[C] Read motor drive section
(1) Take off the rear cover.
( P.4-2 "[B] Rear cover")
(2) Take off the fan motor.
( P.4-18 "[A] Fan motor (M4)")
(3) Disconnect 1 connector, and then remove 1
spring. (Spring: Outside diameter of coil –
ø10.2 mm, active coils – 12.5)
Fig.4-51
(4) Remove 3 screws, and then take off the read
motor with its bracket.
Note: Note:
When the unit is being assembled, tempo-
rarily tighten the screws removed at step (3),
and then attach the spring removed at step
(2). Then fully tighten these screws.
Fig.4-52
(5) Remove 1 spring. (Spring: Outside diameter
of coil –ø8.8 mm, active coils – 12.5)
(6) Release the harness from 2 harness clamps.
Fig.4-53
Connector
Spring
Read motor
Screw
Harness clamp
Spring
Harness clamp